关于H3C S5500-HI交换机做UPE后主备链路切换时间经验分享
一、 组网图:
二、 测试步骤:
1、 在S5500HI部署VPLS功能,使其内部网络与NPE-3内部网络通过VPLS互联互通。(配置略)
2、 S5500HI作为UPE设备,正常情况下,数据通过NPE-1传递给NPE-3;NPE-2作为备份链路中的设备。
VsiID VsiType PeerAddr InLabel OutLabel LinkID VCState
500 vlan 3.3.3.3 1079 1075 2 block
500 vlan 2.2.2.2 1088 1105 1 up
3、 当UPE与往NPE-1端口shutdown后,PW邻居3.3.3.3状态变为up
[UPE-GigabitEthernet1/0/1]shutdown
[UPE-GigabitEthernet1/0/1]
%Apr 27 06:34:12:911 2000 UPE IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/1 link status is DOWN.
%Apr 27 06:34:13:174 2000 UPE IFNET/3/LINK_UPDOWN: Vlan-interface12 link status is DOWN.
%Apr 27 06:34:13:285 2000 UPE IFNET/5/LINEPROTO_UPDOWN: Line protocol on the interface Vlan-interface12 is DOWN.
%Apr 27 06:34:13:566 2000 UPE LDP/5/LDP_SESSION_DOWN: Session(2.2.2.2:0, public instance)'s state changed to down.
[UPE-GigabitEthernet1/0/1]display vpls connection
Total 1 connection(s),
connection(s): 1 up, 0 block, 0 down, 1 ldp, 0 bgp
VSI Name: aaa Signaling: ldp
VsiID VsiType PeerAddr InLabel OutLabel LinkID VCState
500 vlan 3.3.3.3 1079 1075 2 up
4、 在S5500HI上配置dual-npe revertive wtr-time确定故障链路恢复后流量等待切换的时间1 min。
vsi aaa static
pwsignal ldp
vsi-id 500
peer 2.2.2.2 backup-peer 3.3.3.3
dual-npe revertive wtr-time 1
5、 当UPE与NPE-1互联端口恢复后,观察PW状态切换情况。
[UPE-GigabitEthernet1/0/1]und shutdown
%Apr 27 06:34:24:078 2000 UPE IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/1 link status is UP.
%Apr 27 06:34:24:189 2000 UPE IFNET/3/LINK_UPDOWN: Vlan-interface12 link status is UP.
%Apr 27 06:34:24:314 2000 UPE IFNET/5/LINEPROTO_UPDOWN: Line protocol on the interface Vlan-interface12 is UP.
%Apr 27 06:34:24:455 2000 UPE LDP/5/LDP_SESSION_UP: Session(2.2.2.2:0, public instance)'s state changed to up.
%Apr 27 06:34:24:595 2000 UPE LLDP/6/LLDP_CREATE_NEIGHBOR: New neighbor created on Port GigabitEthernet1/0/1 (IfIndex 9437184), Chassis ID is 000f-e2f4-08d2, Port ID is GigabitEthernet1/0/1.
[UPE-GigabitEthernet1/0/1]dis vpls connection
Total 2 connection(s),
connection(s): 1 up, 1 block, 0 down, 2 ldp, 0 bgp
VSI Name: aaa Signaling: ldp
VsiID VsiType PeerAddr InLabel OutLabel LinkID VCState
500 vlan 3.3.3.3 1079 1075 2 up
500 vlan 2.2.2.2 1088 1105 1 block
[UPE-GigabitEthernet1/0/1]dis vpls connection
Total 2 connection(s),
connection(s): 1 up, 1 block, 0 down, 2 ldp, 0 bgp
VSI Name: aaa Signaling: ldp
VsiID VsiType PeerAddr InLabel OutLabel LinkID VCState
500 vlan 3.3.3.3 1079 1075 2 block
500 vlan 2.2.2.2 1088 1105 1 up
当UPE与NPE-1端口UP后,设备提示LDP_SESSION_UP后,开始计时。PW邻居2.2.2.2从block到up状态切换时间花费1分40秒。切换过程中两端内网用户无丢包情况。
三、 测试疑问及解答:
疑问:
根据设备部署的策略dual-npe revertive wtr-time 1,当链路恢复后,数据流切换需等待1分40秒左右,而非1分钟。
解答:
由于设备wtr-time最小计时单位为:min,设备该计时器为1 min。实际含义表示设备每隔1分钟对LDP Session进行探测。当链接状态恢复(UP)时,可能该时间点还不是下次探测的时间,因此造成时间上的误差。
举例:
当wtr-time设为2min时,主链路故障。在14:01:20时链路恢复LDP Session UP。设备上一次探测的时间点为14:01:00,由于探测周期为1min,因此设备在14:02:00才再次开始探测。当探测到状态恢复后等待设备的2分钟流量切换,其最后切换完成时间为14:04:00。
四、 测试总结:
由于设备wtr-time计时器单位设定为1分钟,因此UPE故障链路恢复时,流量切换时间为管理员手工设定的时间+1分钟的范围内。
S7500E、S10500、S5800同样适用于该文档。
该案例暂时没有网友评论
✖
案例意见反馈
亲~登录后才可以操作哦!
确定你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作