影响范围:
当服务器SmartStorageBattery (SSB)电池出现故障时,会导致阵列卡缓存告警:
the smart array cache is permanently disabled.
这样的告警会导致备件被错误的更换, 当电池出现故障时,会导致阵列卡写缓存被禁用,但是这样并不会影响系统运行,系统只会在降级状态下运行。
具体症状如下:
1,系统健康度闪黄灯,表明服务器处于降级状态。The system health LED will blink amber, indicating the server is in a degraded condition.
2. iLO 工具将显示阵列卡缓存为"failed" 并且SSB 状态是 OK.
3. HPSSA、HPSSACLI显示阵列卡缓存被永久禁用。 "permanently disabled."
通过hpssacli工具查看Cache Status Details: Cable Error , 此告警表明电池故障。
Cache Board Present: True
Cache Status: Permanently Disabled
Cache Status Details: Cable Error
Cache Ratio: 10% Read / 90% Write
Drive Write Cache: Disabled
Total Cache Size: 2.0 GB
Total Cache Memory Available: 1.8 GB
No-Battery Write Cache: Disabled
SSD Caching RAID5 WriteBack Enabled: True
SSD Caching Version: 2
Cache Backup Power Source: Batteries
Battery/Capacitor Count: 1
Battery/Capacitor Status: Recharging
使用HP SSACLI工具 运行如下命令 显示阵列卡状态:
hpssacli ctrl slot=0 show status
命令输出将显示缓存为“永久禁用”,为了判断阵列卡电池是否故障,需要通过查看cache status details 的状态值,如果是“cable error”那个电池需要更换。否则,需要升级阵列卡固件,BIOS,ILO FW到最新版本修复误报警。
该案例暂时没有网友评论
✖