不涉及
iMC SSA E0703P08升级至E0705失败,报错截图如下:
1、收集报错日志dmalog发现有如下记录:
2021-01-15 14:41:12 [ERROR] [SwingWorker-pool-1-thread-9] [com.h3c.imc.deploy.tasks.BuildDatabaseTask$DatabaseBuilderWorker::doInBackground(938)] Execute database script error! return value: 4. For details, see log file: /etc/iMC-Reserved/log/dbresult_2021011514411140.log
2021-01-15 14:41:12 [ERROR] [SwingWorker-pool-1-thread-9] [com.h3c.imc.deploy.dma.SlaveUpdateWorker::doWork(205)] Task execute failed
2、根据dmalog错误记录指向,进一步查看/etc/iMC-Reserved/log/dbresult_2021011514411140.log日志:
update db objects of imc ssa
Executing "/opt/iMC/tmp/dbscript_2021011514411141/oracle/7.3E0705_zh.sql" ...
alter table tbl_cim_server_alarm rename column keep to keeps
*
ERROR at line 1: ORA-00957: duplicate column name
3、该报错经确认有产品已知问题:U-Center E0707的版本说明书中存在相关说明,截图如下:
方法一:建议根据规避办法操作即可:
• 规避措施:升级iMC PLAT 7.3 (E0705)和升级iMC PLAT 7.3 (E0705P04)版本时先不升级SSA组件,升级U-Center 7.3 (E0707)时再升级SSA组件。
方法二:对于实在无法绕过E0705版本的,可以通过如下方法:
(1)将iMC\deploy\components\iMC-SSA\V700R010B01D009\client\7.3E0705文件夹下的放到下面的路径 iMC\deploy\components\iMC-SSA\V700R001B06D027\client\7.3E0705 中;
(2)如果没有iMC\deploy\components\iMC-SSA\V700R010B01D009\client\7.3E0705,则将0707版本安装包下路径install\components\iMC-CIM\client\7.3E0705下的放到下面路径iMC\deploy\components\iMC-SSA\V700R001B06D027\client\7.3E0705 中;
PS:推荐方法一
✖