MSA1060,新上架安装,所有连接主机的光纤口灯不亮
1.确认光纤线连接正确
2.确认光纤线正常
3.确认SFP模块兼容
4.确认存储控制器正常
5.收集存储日志分析如下
存储四个端口都是未连接状态:
eventlog中记录如下:
A100 2023-05-14 16:25:02 464 WARNING An unsupported SFP was detected. The SFP is not compatible with this system. You must use an SFP that is qualified for use in this system. (host port: 2)
和现场确认,现场使用SFP模块为:C8R23B
876141-001 MSA 8Gb short wave Fibre Channel small form factor pluggable transceiver
MSA1060兼容的SFP模块是16GB:C8R24B
HPE MSA 16Gb Short Wave Fibre Channel SFP+ 4-pack Transceiver
更换兼容的SFP模块
该案例暂时没有网友评论
✖
案例意见反馈
亲~登录后才可以操作哦!
确定你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作