设备型号和版本:S5130S-52S-PWR-HI Release 6343P08
现场反馈使用5130交换机替换3600交换机后,部分话机在接完电话后会重启,日志也有告警
%Oct 14 11:31:44:639 2024 BDC-CCU-AS-HC5130-01_20F POE/1/PSE_PORT_ON_OFF_CHANGE: Trap <pethPsePortOnOffNotification>: PSE 4, IfIndex 4, Detection Status 6.
%Oct 14 11:31:51:815 2024 BDC-CCU-AS-HC5130-01_20F IFNET/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet1/0/4 changed to up.
%Oct 14 11:31:51:822 2024 BDC-CCU-AS-HC5130-01_20F IFNET/5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet1/0/4 changed to up.
%Oct 14 11:31:53:390 2024 BDC-CCU-AS-HC5130-01_20F POE/1/PSE_PORT_ON_OFF_CHANGE: Trap <pethPsePortOnOffNotification>: PSE 4, IfIndex 4, Detection Status 3.
1、仅交换机端口供电,交换机配置POE非标监测和强制供电,故障依旧
2、仅外接电源供电,交换机关闭POE供电功能,插上话机自带的电源适配器,正常
3、查看设备供电情况,设备还剩1585.3(W),如果怀疑是功率不足,概率不大
===============display poe device===============
Slot 1:
PSE ID Slot No. SSlot No. PortNum MaxPower(W) State Model
4 1 0 48 1680.0 On LSPPSE48B
=========================================================
===============display poe interface===============
Interface PoE Priority CurPower Oper IEEE Detection
(W) Class Status
GE1/0/1 Enabled Low 2.7 On 1 Delivering Power
GE1/0/2 Enabled Low 2.7 On 1 Delivering Power
GE1/0/3 Enabled Low 2.8 On 1 Delivering Power
GE1/0/4 Enabled Low 2.8 On 1 Delivering Power
GE1/0/5 Enabled Low 2.7 On 1 Delivering Power
GE1/0/6 Enabled Low 2.7 On 1 Delivering Power
GE1/0/7 Enabled Low 2.6 On 1 Delivering Power
GE1/0/8 Enabled Low 2.7 On 1 Delivering Power
GE1/0/9 Enabled Low 2.8 On 1 Delivering Power
GE1/0/10 Enabled Low 2.7 On 1 Delivering Power
GE1/0/11 Enabled Low 2.7 On 1 Delivering Power
GE1/0/12 Enabled Low 0.0 Off 0 Searching
GE1/0/13 Enabled Low 0.0 Off 0 Searching
GE1/0/14 Enabled Low 0.0 Off 0 Searching
GE1/0/15 Enabled Low 0.0 Off 0 Searching
GE1/0/16 Enabled Low 0.0 Off 0 Searching
GE1/0/17 Enabled Low 2.7 On 1 Delivering Power
GE1/0/18 Enabled Low 2.7 On 1 Delivering Power
GE1/0/19 Enabled Low 0.0 Off 0 Searching
GE1/0/20 Enabled Low 2.8 On 1 Delivering Power
GE1/0/21 Enabled Low 2.8 On 1 Delivering Power
GE1/0/22 Enabled Low 0.0 Off 0 Searching
GE1/0/23 Enabled Low 0.0 Off 0 Searching
GE1/0/24 Enabled Low 0.0 Off 0 Searching
GE1/0/25 Enabled Low 0.0 Off 0 Searching
GE1/0/26 Enabled Low 0.0 Off 0 Searching
GE1/0/27 Enabled Low 3.0 On 1 Delivering Power
GE1/0/28 Enabled Low 3.0 On 1 Delivering Power
GE1/0/29 Enabled Low 2.9 On 1 Delivering Power
GE1/0/30 Enabled Low 3.0 On 1 Delivering Power
GE1/0/31 Enabled Low 2.4 On 1 Delivering Power
GE1/0/32 Enabled Low 2.8 On 1 Delivering Power
GE1/0/33 Enabled Low 3.2 On 1 Delivering Power
GE1/0/34 Enabled Low 0.0 Off 0 Searching
GE1/0/35 Enabled Low 0.0 Off 0 Searching
GE1/0/36 Enabled Low 2.7 On 1 Delivering Power
GE1/0/37 Enabled Low 0.0 Off 0 Searching
GE1/0/38 Enabled Low 2.4 On 1 Delivering Power
GE1/0/39 Enabled Low 3.0 On 1 Delivering Power
GE1/0/40 Enabled Low 2.8 On 1 Delivering Power
GE1/0/41 Enabled Low 2.8 On 1 Delivering Power
GE1/0/42 Enabled Low 2.9 On 1 Delivering Power
GE1/0/43 Enabled Low 2.8 On 1 Delivering Power
GE1/0/44 Enabled Low 2.9 On 1 Delivering Power
GE1/0/45 Enabled Low 2.7 On 1 Delivering Power
GE1/0/46 Enabled Low 2.8 On 1 Delivering Power
GE1/0/47 Enabled Low 2.8 On 1 Delivering Power
GE1/0/48 Enabled Low 2.9 On 1 Delivering Power
--- On State Ports: 34; Used: 94.7(W); Remaining: 1585.3(W) ---
4、现场交换机和话机通过配线架连接,从交换机到配线架的跳线已经更换。福禄克测试通过
5、产品线分析诊断信息,发现port4、27、41口有POE过电流掉电记录,与现场反馈现象(5130-1的4、27、41口连IP话机存在反复重启)一致。
i_s_cnt p_d_cnt o_cnt s_cnt m_a_cnt
port0 213 0 0 0 0
port1 224 0 0 0 0
port2 233 0 0 0 0
port3 578 0 3 0 1
port4 260 0 0 0 0
port5 272 0 0 0 0
port6 293 0 0 0 0
port7 306 0 0 0 0
port8 313 0 0 0 0
port9 329 0 0 0 0
port10 671 0 0 0 1
port11 190554 0 0 0 0
port12 188925 0 0 0 0
port13 187631 0 0 0 0
port14 188933 0 0 0 0
port15 187608 0 0 0 0
port16 482 0 0 0 0
port17 489 0 0 0 0
port18 189416 0 0 0 0
port19 515 0 0 0 0
port20 520 0 0 0 0
port21 189642 0 0 0 0
port22 189589 0 0 0 0
port23 189585 0 0 0 0
port24 186807 0 0 0 0
port25 186772 0 0 0 0
port26 537 0 1 0 0
port27 809 0 0 0 4
port28 554 0 0 0 0
port29 1958 0 0 0 3
port30 562 0 0 0 0
port31 568 0 0 0 0
port32 579 0 0 0 0
port33 189000 0 0 0 0
port34 189010 0 0 0 0
port35 586 0 0 0 0
port36 190011 0 0 0 0
port37 596 0 0 0 0
port38 614 0 0 0 0
port39 625 0 0 0 0
port40 808 0 8 0 1
port41 639 0 0 0 0
port42 648 0 0 0 0
port43 660 0 0 0 0
port44 666 0 0 0 0
port45 680 0 0 0 0
port46 689 0 0 0 0
port47 690 0 0 0 0
因此POE震荡原因:客户处话机为Class1终端,与交换机分级结果也一致(如下诊断信息高亮部分)。根据IEEE标准Class1供电功率最大为4W,如终端电话功耗超过4W就会触发交换机侧过流掉电,掉电后交换机又会重新检测分级上电,因此会出现客户处的POE震荡。
===============display poe interface===============
Interface PoE Priority CurPower Oper IEEE Detection
(W) Class Status
GE1/0/1 Enabled Low 2.7 On 1 Delivering Power
GE1/0/2 Enabled Low 2.7 On 1 Delivering Power
GE1/0/3 Enabled Low 2.8 On 1 Delivering Power
GE1/0/4 Enabled Low 2.8 On 1 Delivering Power
将端口最大功率强制到25W,避免部分电话功率超过4W触发掉电。
震荡端口下配置命令行 poe max-power 25000
该案例暂时没有网友评论
✖