现场设备从7178升级至7568P01,后出现0/0/6和0/0/7号端口无法UP的问题,现场模块用的是第三方的模块,现场尝试强制双工和速率,但是依旧无法UP,回退版本后正常
端口有其他友商模块正常使用,确认6、7口模块寄存器是否正确
probe视图下可收集如下信息:
dis hardware internal transceiver register interface Ten 0/0/6 device a0 add 0 length 128
dis hardware internal transceiver register interface Ten 0/0/6 device a2 add 0 length 128
dis hardware internal transceiver register interface Ten 0/0/6 device a2 add 80 length 128
dis hardware internal transceiver register interface Ten 0/0/7 device a0 add 0 length 128
dis hardware internal transceiver register interface Ten 0/0/7 device a2 add 0 length 128
dis hardware internal transceiver register interface Ten 0/0/7 device a2 add 80 length 128
最终确认寄存器值存在问题,光模块寄存器有问题,寄存器0x24 字节被写成了1,在新版本会被识别成25G光模块,导致不UP。
[HengYangXian_H3C_S7610-probe]dis hardware internal transceiver register interfa
ce Ten 0/0/6 device a0 add 0 length 128
Ten-GigabitEthernet0/0/6 transceiver device a0 register information:
0000: 03 04 07 80 00 00 00 00
0008: 00 00 00 06 67 00 50 ff
0010: 00 00 00 00 53 75 6d 69
0018: 74 6f 6d 6f 45 6c 65 63
0020: 74 72 69 63 01 00 00 5f
[HengYangXian_H3C_S7610-probe] dis hardware internal transceiver register interf
ace Ten 0/0/7 device a0 add 0 length 128
Ten-GigabitEthernet0/0/7 transceiver device a0 register information:
0000: 03 04 07 80 00 00 00 00
0008: 00 00 00 06 67 00 50 ff
0010: 00 00 00 00 53 75 6d 69
0018: 74 6f 6d 6f 45 6c 65 63
0020: 74 72 69 63 01 00 00 5f
新版本,平台合入了支持25G光模块的特性。 之前老版本不关注这个字节,但新版本新增25G光模块支持后,就会去识别这个字节的内容,所以导致升级后出现这样的问题
建议升级后使用我司80KM SFP+模块