两台M9006建立IRF,使用Ten-GigabitEthernet1/4/0/19-22作为堆叠口,Ten-GigabitEthernet1/4/0/23和Ten-GigabitEthernet2/4/0/23加入三层聚合口1024用于BFD检测。
现场发现BFD MAD检测状态为faulty,于是将两台设备脱离irf,两台设备的三层聚合口的成员接口退出聚合口直连测试,发现接口状态为Link-Aggregation interface down。
MAD BFD enabled interface: Route-Aggregation1024
MAD status : Faulty
Member ID MAD IP address Neighbor MAD status
1 192.168.1.1/30 2 Faulty
2 192.168.1.2/30 1 Faulty
Ten-GigabitEthernet1/4/0/23
Current state: DOWN ( Link-Aggregation interface down )
Line protocol state: DOWN
Description: To_BFD
Bandwidth: 10000000 kbps
Maximum transmission unit: 1500
interface Blade-Aggregation1
link-aggregation blade Blade3fw
===============display device verbose===============
Chassis Slot Type State Subslot Soft Ver Patch Ver
1 0 NSQ1SUPB0 Master 0 M9006-9131P30 None
1 1 NSQ1SUPB0 Standby 0 M9006-9131P30 None
1 2 NSQM1FWDFGB0 Normal 0 M9006-9131P30 None
CPU 1 Normal 0 M9006-9131P30
1 3 NSQM1FWDFGB0 Normal 0 M9006-9131P30 None
CPU 1 Normal 0 M9006-9131P30
1 4 NSQ1TGS32SF0 Normal 0 M9006-9131P30 None