两台S6520X通过1/1/2和2/1/2口进行堆叠,堆叠口位于子卡上
现场互联堆叠口1/1/2和2/1/2出现闪断,诊断信息显示接口无错包,收发光正常
%Dec 12 20:47:43:981 2021 SH-SH-HB-RN02&3-TOR-1&2.Mgmt IFNET/3/PHY_UPDOWN: Physical state on the interface FortyGigE1/1/2 changed to down.
%Dec 12 20:47:43:966 2021 SH-SH-HB-RN02&3-TOR-1&2.Mgmt IFNET/3/PHY_UPDOWN: Physical state on the interface FortyGigE2/1/2 changed to down.
查看接口收发光正常
FortyGigE1/1/2 transceiver diagnostic information:
Current diagnostic parameters:
[module] Temp.(°C) Voltage(V)
32 3.45
[channel] Bias(mA) RX power(dBm) TX power(dBm)
1 30.17 0.63 1.51
2 30.92 0.57 -0.18
3 30.80 -0.27 0.36
4 30.86 1.22 -0.57
Alarm thresholds:
Temp.(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
High 80 3.70 75.00 4.50 4.50
Low -10 2.90 10.00 -12.50 -6.50
FortyGigE2/1/2 transceiver diagnostic information:
Current diagnostic parameters:
[module] Temp.(°C) Voltage(V)
31 3.47
[channel] Bias(mA) RX power(dBm) TX power(dBm)
1 30.77 -0.31 0.94
2 30.80 -2.45 0.50
3 30.86 0.57 -0.65
4 30.83 0.50 -1.19
Alarm thresholds:
Temp.(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
High 80 3.70 75.00 4.50 4.50
Low -10 2.90 10.00 -12.50 -6.50
继续排查日志发现如下光模块被拔出的信息,但是现场并未人为插拔模块
%Dec 12 20:47:39:574 2021 SH-SH-HB-RN02&3-TOR-1&2.Mgmt OPTMOD/4/MODULE_OUT: -Slot=2; FortyGigE2/1/2: Transceiver absent.
通过上述现象确认是如下已知软件问题导致
1. 202005060377:
问题现象:低概率误报光模块被拔出。
问题产生条件:设备插入子卡并在此子卡上插入模块光使用。
建议升级到R6526版本解决