典型AC-fit AP组网
AP频繁发生power on重启
某局点反馈AP发生频繁power on重启,且和业务量强相关,AP重启原因均为power on
(1)现场反馈AP是新采购的,且已经升级至官网最新版本,理论上不应该是版本问题;
(2)该型号AP为wifi6高端AP,整机16条空间流,对供电规格要求较高,最高需要52.5W;
(3)同步分析交换机诊断,发现交换机诊断里面有过载记录;
===============debug poe port-mib 6===============
CONTENT
PbPortMIBCnt[uiI].uiInvalidSingCnt
PbPortMIBCnt[uiI].uiPowerDenidedCnt
PbPortMIBCnt[uiI].uiOverLoadCnt
PbPortMIBCnt[uiI].uiShortCnt
PbPortMIBCnt[uiI].uiMpAbsentCnt
i_s_cnt p_d_cnt o_cnt s_cnt m_a_cnt
port0 1232 0 16 0 3
port1 3544 1 26 0 6
port2 1848 0 25 0 3
port3 1973 0 26 0 4
port4 1928 0 18 0 3
(4)交换机日志中也有poe状态变化日志
%@1879269%May 17 10:34:44:972 2022 SW/3/PHY_UPDOWN: Physical state on the interface GigabitEthernet6/0/6 changed to down.
%@1879270%May 17 10:34:45:001 2022 SW /5/LINK_UPDOWN: Line protocol state on the interface GigabitEthernet6/0/6 changed to down.
%@1879271%May 17 10:34:46:114 2022 SW POE/1/PSE_PORT_ON_OFF_CHANGE: -Slot=6;
Trap <pethPsePortOnOffNotification>: PSE 19, IfIndex 321, Detection Status 1.
%@1879272%May 17 10:34:49:707 2022 SW POE/1/PSE_PORT_ON_OFF_CHANGE: -Slot=6;
Trap <pethPsePortOnOffNotification>: PSE 19, IfIndex 321, Detection Status 3.
(4)因此判定:现场S5130S-28S-HPWR-EI交换机单口最高支持30W,但现场AP所需功率远超30W,故而导致AP超功率掉电
更换支持802.3bt供电交换机