客户两台S6800-32Q交换机堆叠后在命令行出现大量告警,并且堆叠无法成功,以下为日志内容:
%Oct 12 14:05:48:319 2019 ASW-201-B11.AM15 DRVPLAT/4/DrvDebug:
The port Forty1/0/54 can't receive irf pkt, please check.
%Oct 12 14:05:57:433 2019 ASW-201-B11.AM15 DRVPLAT/4/DrvDebug:
The port Forty1/0/54 can't receive irf pkt, please check.
%Oct 12 14:06:06:500 2019 ASW-201-B11.AM15 DRVPLAT/4/DrvDebug:
The port Forty1/0/54 can't receive irf pkt, please check.
%Oct 12 14:06:15:571 2019 ASW-201-B11.AM15 DRVPLAT/4/DrvDebug:
The port Forty1/0/54 can't receive irf pkt, please check.
%Oct 12 14:06:24:702 2019 ASW-201-B11.AM15 DRVPLAT/4/DrvDebug:
The port Forty1/0/54 can't receive irf pkt, please check.
排查设备配置无异常后收集设备诊断信息,诊断信息中显示除了IRF端口不收包外还有以下告警:
根据官网IRF限制可以得到,在建立堆叠的两台设备max-ecmp-num必须一致。
分别查询两台设备的最大等价路由条数:
堆叠A设备:
<H3C> display max-ecmp-num
Max-ECMP-Num in use: 10
Max-ECMP-Num at the next reboot: 10
堆叠B设备:
<H3C> display max-ecmp-num
Max-ECMP-Num in use: 40
Max-ECMP-Num at the next reboot: 40
经过了解现场设备在配置前已经恢复了出厂设置,设备因批次问题即使同型号的设备最大等价路由条数也有可能不同,需要修改两台设备最大等价路由条数一致,将堆叠A设备max-ecmp-num修改为10后两台设备可以正常建立堆叠。
修改命令:
<H3C>system-view
[H3C]max-ecmp-num 10